Accepted Power Analyzers
Note: The minimum PTDaemon interface version required for publishable results changes over time and is discussed in the PTDaemon Interface Update Process.
Please see Compatibility Across OS and Connection Types for information on OS and connection type support details for each device.
List of Accepted Power Analyzers
| Manufacturer | Model | First Supported in PTDaemon Version | Restrictions on Use |
|---|---|---|---|
| Chroma | 66202 | v1.3.9 | Valid only for low shunt ranges (0.01, 0.1, 0.4, 2.0 A RMS) and the 20A RMS high shunt range. |
| Chroma | 66203 & 66204 | v1.6.3 | Only the use of one channel at a time is supported. |
| Chroma | 66203 & 66204 DC | v1.7.1 | See above. |
| Chroma | 66205 | v1.9.0 | |
| Chroma | 66205 DC | v1.9.0 | |
| Hioki | 3334 | v1.3.10 | Valid only for load currents less than 14.167A. With PTDaemon interface versions >=v1.4.0 and Hioki firmware version v1.10, the maximum valid load current must be less than 17.334A. |
| Hioki | PW3335 | v1.8.0 | Maximum valid load currents less than 20A |
| Hioki | PW3335 DC | v1.8.1 | |
| Hioki | PW3336 Multichannel | v1.10.0 | Maximum valid load currents less than 33.3A/channel |
| Hioki | PW3336 1-Channel | v1.8.0 | Maximum valid load currents less than 33.3A/channel |
| Hioki | PW3337 Multichannel | v1.10.0 | Maximum valid load currents less than 33.3A/channel |
| Hioki | PW3337 1-Channel | v1.8.0 | Maximum valid load currents less than 33.3A/channel |
| Infratek | 107A-1 | v1.2 | Valid only for load currents less than half the selected current range in order to satisfy the required minimum crest factor value of 3. |
| Instek | GPM-8212 | v1.2 | Valid only for load currents less than 10A. |
| Instek | GPM-8213 | v1.9.2 | |
| Instek | GPM-8310 | v1.9.2 | |
| Newtons4th | PPA5x0 | v1.6.2 | Only the use of one channel at a time is supported. |
| Newtons4th | PPA5x0 DC | v1.7.0 | See above. |
| Newtons4th | PPA15x0 | v1.4.2 | Only the use of channel 1 is supported previous to PTDaemon interface v1.6.1. Channels 1-3 supported with PTDaemon interface v1.6.1. HC and LC Models supported with 1.6.2 |
| Newtons4th | PPA55x0 | v1.6.1 | Only the use of channel 1 is supported. HC and LC Models supported with 1.6.2 |
| Tektronix | PA1000 | v1.7.1 | |
| Tektronix | PA1000 DC | v1.7.1 | |
| Voltech | PM1000+ | v.1.4.1 | Requires firmware version 4.22 or newer. Please align to PTDaemon interface v1.6.0 if utilizing this analyzer. |
| Xitron | 2801 | v1.4.0 | |
| Xitron | 2802 | v1.3 | Only the use of one channel at a time is supported. |
| Yokogawa | WT210 | v1.0 | Minimum firmware revision required is v1.11. In the case where an external current sensor option is installed, it must be disabled, and, in this scenario, the minimum PTDaemon interface version required is v1.3.10. |
| Yokogawa | WT210 DC | v1.7.0 | See above |
| Yokogawa | WT310 & WT310e | v1.6.0, v1.8.0 | |
| Yokogawa | WT310 & WT310e DC | v1.7.0 | |
| Yokogawa | WT330 & WT330e Multichannel | 2 or 3 consecutive channels may be used. | |
| Yokogawa | WT330 & WT330e 1-Channel | v1.7.0 | |
| Yokogawa | WT500 1-Channel | v1.3.9 | Only the use of one channel at a time is supported. |
| Yokogawa | WT500 Multichannel | v1.10.0 | |
| Yokogawa | WT500 DC | v1.7.0 | |
| Yokogawa | WT1800 | v1.4.2 | Only the use of one channel at a time is supported. In the case where an external current sensor option is installed, it must be disabled. |
| Yokogawa | WT1800E | v1.9.0 | Only the use of one channel at a time is supported. In the case where an external current sensor option is installed, it must be disabled. |
| Yokogawa | WT5000 1-Channel | v1.9.1 | Only the use of one channel at a time is supported. |
| Yokogawa | WT5000 DC | v1.9.1 | |
| Yokogawa | WT5000 Multichannel | v1.11.1 | |
| ZES Zimmer | LMG95 | v1.2 | |
| ZES Zimmer | LMG95 DC | v1.7.0 | |
| ZES Zimmer | LMG450 1-Channel | v1.0 | |
| ZES Zimmer | LMG450 Multichannel | v1.11.0 | |
| ZES Zimmer | LMG500 1-Channel | v1.2 | |
| ZES Zimmer | LMG500 Multichannel | v1.11.0 | |
| ZES Zimmer | LMG610 | v1.9.2 | Channel module types A, B, and C are supported. |
| ZES Zimmer | LMG611 | v1.11.0 | Channel module types A, B, and C are supported. |
| ZES Zimmer | LMG641 1-Channel | v1.9.2 | |
| ZES Zimmer | LMG641 Multichannel | v1.11.0 | |
| ZES Zimmer | LMG671 1-Channel | v1.9.2 | |
| ZES Zimmer | LMG671 Multichannel | ||
| ZLG | PA310 1-Channel | v1.11.1 | |
| ZLG | PA310 DC | v1.11.1 |