Accepted Power Analyzers

Note: The minimum PTDaemon interface version required for publishable results changes over time and is discussed in the PTDaemon Interface Update Process.

Please see Compatibility Across OS and Connection Types for information on OS and connection type support details for each device.

List of Accepted Power Analyzers

ManufacturerModelFirst Supported in PTDaemon VersionRestrictions on Use
Chroma66202v1.3.9Valid only for low shunt ranges (0.01, 0.1, 0.4, 2.0 A RMS) and the 20A RMS high shunt range.
Chroma66203 & 66204v1.6.3Only the use of one channel at a time is supported.
Chroma66203 & 66204 DCv1.7.1See above.
Chroma66205v1.9.0
Chroma66205 DCv1.9.0
Hioki3334v1.3.10Valid only for load currents less than 14.167A. With PTDaemon interface versions >=v1.4.0 and Hioki firmware version v1.10, the maximum valid load current must be less than 17.334A.
HiokiPW3335v1.8.0Maximum valid load currents less than 20A
HiokiPW3335 DCv1.8.1
HiokiPW3336 Multichannelv1.10.0Maximum valid load currents less than 33.3A/channel
HiokiPW3336 1-Channelv1.8.0Maximum valid load currents less than 33.3A/channel
HiokiPW3337 Multichannelv1.10.0Maximum valid load currents less than 33.3A/channel
HiokiPW3337 1-Channelv1.8.0Maximum valid load currents less than 33.3A/channel
Infratek107A-1v1.2Valid only for load currents less than half the selected current range in order to satisfy the required minimum crest factor value of 3.
InstekGPM-8212v1.2Valid only for load currents less than 10A.
InstekGPM-8213v1.9.2
InstekGPM-8310v1.9.2
Newtons4thPPA5x0v1.6.2Only the use of one channel at a time is supported.
Newtons4thPPA5x0 DCv1.7.0See above.
Newtons4thPPA15x0v1.4.2Only the use of channel 1 is supported previous to PTDaemon interface v1.6.1. Channels 1-3 supported with PTDaemon interface v1.6.1. HC and LC Models supported with 1.6.2
Newtons4thPPA55x0v1.6.1Only the use of channel 1 is supported. HC and LC Models supported with 1.6.2
TektronixPA1000v1.7.1
TektronixPA1000 DCv1.7.1
VoltechPM1000+v.1.4.1Requires firmware version 4.22 or newer. Please align to PTDaemon interface v1.6.0 if utilizing this analyzer.
Xitron2801v1.4.0
Xitron2802v1.3Only the use of one channel at a time is supported.
YokogawaWT210v1.0Minimum firmware revision required is v1.11. In the case where an external current sensor option is installed, it must be disabled, and, in this scenario, the minimum PTDaemon interface version required is v1.3.10.
YokogawaWT210 DCv1.7.0See above
YokogawaWT310 & WT310ev1.6.0, v1.8.0
YokogawaWT310 & WT310e DCv1.7.0
YokogawaWT330 & WT330e Multichannel2 or 3 consecutive channels may be used.
YokogawaWT330 & WT330e 1-Channelv1.7.0
YokogawaWT500 1-Channelv1.3.9Only the use of one channel at a time is supported.
YokogawaWT500 Multichannelv1.10.0
YokogawaWT500 DCv1.7.0
YokogawaWT1800v1.4.2Only the use of one channel at a time is supported. In the case where an external current sensor option is installed, it must be disabled.
YokogawaWT1800Ev1.9.0Only the use of one channel at a time is supported. In the case where an external current sensor option is installed, it must be disabled.
YokogawaWT5000 1-Channelv1.9.1Only the use of one channel at a time is supported.
YokogawaWT5000 DCv1.9.1
YokogawaWT5000 Multichannelv1.11.1
ZES ZimmerLMG95v1.2
ZES ZimmerLMG95 DCv1.7.0
ZES ZimmerLMG450 1-Channelv1.0
ZES ZimmerLMG450 Multichannelv1.11.0
ZES ZimmerLMG500 1-Channelv1.2
ZES ZimmerLMG500 Multichannelv1.11.0
ZES ZimmerLMG610v1.9.2Channel module types A, B, and C are supported.
ZES ZimmerLMG611v1.11.0Channel module types A, B, and C are supported.
ZES ZimmerLMG641 1-Channelv1.9.2
ZES ZimmerLMG641 Multichannelv1.11.0
ZES ZimmerLMG671 1-Channelv1.9.2
ZES ZimmerLMG671 Multichannel
ZLGPA310 1-Channelv1.11.1
ZLGPA310 DCv1.11.1