Dell Inc. PowerEdge R570 SPECpower_ssj2008 = 21,089 overall ssj_ops/watt
Test Sponsor: Dell Inc. SPEC License #: 6573 Test Method: Single Node
Tested By: Dell Inc. Test Location: Round Rock, TX, USA Test Date: Mar 10, 2025
Hardware Availability: Mar-2025 Software Availability: Oct-2024 Publication: Mar 26, 2025
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 99.7% 12,828,833 520 24,681
90% 90.0% 11,578,878 512 22,632
80% 80.0% 10,294,592 437 23,564
70% 70.0% 9,004,004 377 23,890
60% 60.0% 7,713,095 331 23,333
50% 50.0% 6,434,362 286 22,464
40% 40.0% 5,151,014 246 20,936
30% 30.0% 3,864,113 213 18,138
20% 20.0% 2,573,535 186 13,844
10% 10.0% 1,291,449 157 8,229
Active Idle 0 90.0 0
∑ssj_ops / ∑power = 21,089
Graph of results
System Under Test
Set: 'sut'
Set Identifier: sut
Set Description: System Under Test
# of Identical Nodes: 1
Comment: SUT
Hardware
Hardware Vendor: Dell Inc.
Model: PowerEdge R570
Form Factor: 2U
CPU Name: Intel Xeon 6787P 2.0 GHz (Intel Turbo Boost Technology up to 3.80 GHz)
CPU Characteristics: 86-Core, 2.00 GHz, 336MB L3 Cache
CPU Frequency (MHz): 2000
CPU(s) Enabled: 86 cores, 1 chip, 86 cores/chip
Hardware Threads: 172 (2 / core)
CPU(s) Orderable: 1 chip
Primary Cache: 32 KB I + 48 KB D on chip per core
Secondary Cache: 2 MB I+D on chip per core
Tertiary Cache: 336 MB I+D on chip per chip
Other Cache: None
Memory Amount (GB): 512
# and size of DIMM: 8 x 64 GB
Memory Details: 64GB 2Rx4 PC5-6400; slots Slots A1-8 populated.
Power Supply Quantity and Rating (W): 1 x 1500
Power Supply Details: 1500W 60mm Titanium - mixed mode, Dell p/n GRD17
Disk Drive: 1 x Dell EC NVMe ISE 7450 RI M.2 80 480GB, Dell p/n 3H1F4
Disk Controller: BOSS controller card, Dell p/n CMFVP
# and type of Network Interface Cards (NICs) Installed: 1 x 1GbE BT 4P Broadcom OCP 3.0, Dell p/n M2PYY
NICs Enabled in Firmware / OS / Connected: 4/4/1
Network Speed (Mbit): 1000
Keyboard: None
Mouse: None
Monitor: None
Optical Drives: No
Other Hardware: None
Software
Power Management: Enabled (see SUT Notes)
Operating System (OS): Microsoft Windows Server 2022 Standard
OS Version: Version 21H2(OS Build 20348.1251)
Filesystem: NTFS
JVM Vendor: Oracle Corporation
JVM Version: Oracle Java HotSpot(TM) 64-Bit Server VM (build 17.0.13+10-LTS-268, mixed mode)
JVM Command-line Options: -server -Xms1300m -Xmx1300m -Xmn1100m -XX:+UseBiasedLocking -XX:+UseParallelGC -XX:ParallelGCThreads=2 -XX:+UseLargePages -XX:LargePageSizeInBytes=2m -XX:InlineSmallCode=1500 -XX:UseAVX=1 -XX:AutoBoxCacheMax=20000 -XX:+OptimizeFill -XX:+AggressiveHeap -XX:FreqInlineSize=2500 -XX:CompileThresholdScaling=220
JVM Affinity: start /NODE [0,2,5,8,10,13] [1,3,4,6,7,9,11,12,14,15] /AFFINITY [0x3,0xC,0x30,0xC0,0x300,0xC00][0x3,0xC,0x30,0xC0,0x300]
JVM Instances: 86
JVM Initial Heap (MB): 1300
JVM Maximum Heap (MB): 1300
JVM Address Bits: 64
Boot Firmware Version: 0.5.62
Management Firmware Version: 1.20.25.00
Workload Version: SSJ 1.2.10
Director Location: Controller
Other Software: None
Boot Firmware Settings
Management Firmware Settings
See SUT Notes
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Dell Inc
Model: PowerEdge R450
CPU Description: 2 x Intel Xeon Silver 4310 CPU, 2.10 GHz
Memory amount (GB): 64
Software
Operating System (OS): Microsoft Windows Server 2022 Datacenter
JVM Vendor: Oracle Corporation
JVM Version: Hotspot(TM) Client VM, version 15.0.2+7 (build 15.0.2+7, mixed mode)
CCS Version: 1.2.6
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: Yokogawa Meters and Instruments Corporation
Model: WT210
Serial Number: 91KA21979
Connectivity: RS-232
Input Connection: Default
Metrology Institute: NIST
Accredited by: TesCom
Calibration Label: T76417
Date of Calibration: 04-Oct-2025
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.11.1-462c978e-20240907
Setup Description: Connected to power supply
Temperature Sensor temp1
Hardware Vendor: Digi International Inc.
Model: Watchport/H
Driver Version: 5.10.26.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 25 mm in front of SUT main airflow intake
Notes
None
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 520 23.3
90% 512 23.3
80% 437 23.3
70% 377 23.3
60% 331 23.3
50% 286 23.3
40% 246 23.3
30% 213 23.3
20% 186 23.3
10% 157 23.3
Active Idle 90.0 23.3
Line Standard Minimum Temperature (°C) Elevation (m)
208V / 60 Hz / 1 phase / 2 wires 23.3 255
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     13,145,125
Calibration 2     12,852,015
Calibration 3     12,872,064
ssj_ops@calibrated=12,862,039
100% 99.7% 12,862,039 12,828,833
90% 90.0% 11,575,836 11,578,878
80% 80.0% 10,289,632 10,294,592
70% 70.0% 9,003,428 9,004,004
60% 60.0% 7,717,224 7,713,095
50% 50.0% 6,431,020 6,434,362
40% 40.0% 5,144,816 5,151,014
30% 30.0% 3,858,612 3,864,113
20% 20.0% 2,572,408 2,573,535
10% 10.0% 1,286,204 1,291,449
Active Idle   0 0
Graph of results