Server Configuration and Availability |
Vendor | Sun Microsystems Inc. |
Hardware Available | Aug 2000 |
Software Available | Apr 2000 |
Date Tested | Aug 2000 |
SFS License Number | 6 |
Licensee Locations | Palo Alto, CA |
CPU, Memory and Power |
Model Name | Sun Enterprise 3500/4500 |
Processor | 400 MHz UltraSPARC II |
# of Processors | 4 |
Primary Cache | 16KBI+16KBD on chip |
Secondary Cache | 8MB(I+D) off chip |
Other Cache | N/A |
UPS | N/A |
Other Hardware | N/A |
Memory Size | 8 GB |
NVRAM Size | 6144MB (256MB per Sun StorEdge T3 controller) |
NVRAM Type | Sun StorEdge T3 write cache |
NVRAM Description | auto-sensing WB/WT depending battery charge |
Server Software |
OS Name and Version | Solaris8_64bit |
Other Software | N/A |
File System | UFS |
NFS version | 3 |
Server Tuning |
Buffer Cache Size | Dynamic |
# NFS Processes | 256 |
Fileset Size | 78.9 GB |
|
Network Subsystem |
Network Type | 1000Mbit Sun GigabitEthernet |
Network Controller Desc. | Sun GigabitEthernet SBus adaptor 2.0 |
Number Networks | 2 (N1,N2) |
Number Network Controllers | 2 |
Protocol Type | UDP |
Switch Type | 2 Extremenetworks Summit2 switch |
Bridge Type | N/A |
Hub Type | N/A |
Other Network Hardware | N/A |
Disk Subsystem and Filesystems |
Number Disk Controllers | 13 |
Number of Disks | 222 |
Number of Filesystems | 24 (F1-F24) |
File System Creation Ops | default |
File System Config | default |
Disk Controller | On-board SCSI-2 |
# of Controller Type | 1 |
Number of Disks | 6 |
Disk Type | 9GB 7200rpm |
File Systems on Disks | OS, swap |
Special Config Notes | |
Disk Controller | FC-AL SBus Adapter (FC100/S)/GBIC |
# of Controller Type | 12 (i=1,2,..,12) |
Number of Disks | 9,9/9,9/9,9/9,9/9,9/9,9/9,9/9,9/9,9/9,9/9,9/9,9 |
Disk Type | 18GB 10000rpm FC-AL (ST118202FC) |
File Systems on Disks | F1,F2/F3,F4/../F23,F24 |
Special Config Notes | Filesystem on RAID5 LUNs (see "Other Notes") |
|