SPECsfs97.v2 Result

Sun Microsystems Inc. :Sun Enterprise 4500
SPECsfs97.v2 =22885 Ops/Sec (Overall Response Time = 5.17 msec)


Performance

Throughput
(ops/sec)
Response
(msec)
22404.3
44964.3
67505.0
90294.9
112665.2
135055.6
157675.7
179615.9
202556.2
225127.5
2288512.5
Performance Graph


Configuration

Server Configuration and Availability
Vendor Sun Microsystems Inc.
Hardware Available Dec 1998
Software AvailableOct 1998
Date TestedMar 1999
SFS License Number6
Licensee LocationsPalo Alto, CA

CPU, Memory and Power
Model Name Sun Enterprise 4500
Processor 400 MHz UltraSPARC II
# of Processors 12
Primary Cache 16KBI+16KBD on chip
Secondary Cache 4MB(I+D) off chip
Other Cache N/A
UPS N/A
Other Hardware N/A
Memory Size 12 GB
NVRAM Size N/A
NVRAM Type N/A
NVRAM DescriptionN/A

Server Software
OS Name and VersionSolaris7_64bit
Other Software N/A
File System UFS
NFS version 2

Server Tuning
Buffer Cache Size Dynamic
# NFS Processes 559
Fileset Size 235.0 GB

Network Subsystem
Network Type 1000Mbit Sun GigabitEthernet
Network Controller Desc. Sun GigabitEthernet SBus adaptor 2.0
Number Networks 2 (N1-N2)
Number Network Controllers2
Protocol Type UDP

Switch Type 2 Extremenetworks Summit2 switch
Bridge Type N/A
Hub Type N/A
Other Network Hardware N/A

Disk Subsystem and Filesystems
Number Disk Controllers 7
Number of Disks 258
Number of Filesystems 224 (F1-F224)
File System Creation Opsdefault
File System Config default

Disk Controller On-board SCSI-2
# of Controller Type 1
Number of Disks 6
Disk Type 4GB 7200rpm
File Systems on Disks OS, swap
Special Config Notes

Disk Controller FC-AL SBus Adapter (FC100/S)/GBIC
# of Controller Type 1/2
Number of Disks 42
Disk Type 9GB 7200rpm FC-AL
File Systems on Disks F1-F42/F43-F84
Special Config Notes Sun StorEdge A5000 each w/ 14 FC-AL drives

Disk Controller FC-AL SBus Adapter (FC100/S)/GBIC
# of Controller Type 3/4
Number of Disks 42
Disk Type 9GB 7200rpm FC-AL
File Systems on Disks F85-F126/F127-F168
Special Config Notes Sun StorEdge A5000 each w/ 14 FC-AL drives

Disk Controller FC-AL SBus Adapter (FC100/S)/GBIC
# of Controller Type 5/6
Number of Disks 42
Disk Type 9GB 7200rpm FC-AL
File Systems on Disks F169-F210/F211-F252
Special Config Notes Sun StorEdge A5000 each w/ 14 FC-AL drives

Load Generator (LG) Configuration
Number of Load Generators 18
Number of Processes per LG14
Biod Max Read Setting 5
Biod Max Write Setting 5

LG Type LG1
LG Model Ultra1-170
Number and Type Processors1 167MHz UltraSPARC
Memory Size 256MB
Operating System Solaris7
Compiler SC4.2
Compiler Options N/A
Network Type SunSwift 100baseT f/w SCSI SBus Adapter

Testbed Configuration
LG #LG TypeNetworkTarget File SystemsNotes
1/2/3LG1N1F1,F19,..,F235/F2,F20,..,F236/F3,F21,..,F237N/A
4/5/6LG1N1F4,F22,..,F238/F5,F23,..,F239/F6,F24,..,F240N/A
7/8/9LG1N1F7,F25,..,F241/F8,F26,..,F242/F9,F27,..,F243N/A
10/11/12LG1N2F10,F28,..,F244/F11,F29,..,F245/F12,F30,..,F246N/A
13/14/15LG1N2F13,F31,..,F247/F14,F32,..,F248/F15,F33,..,F249N/A
16/17/18LG1N2F16,F34,..,F250/F17,F35,..,F251/F18,F36,..,F252N/A


Other Notes


Tue Apr 6 15:11:28 1999