Server Configuration and Availability |
Vendor | EMC Corp. |
Hardware Available | February 2004 |
Software Available | February 2004 |
Date Tested | February 2004 |
SFS License Number | 47 |
Licensee Locations | Hopkinton, MA |
CPU, Memory and Power |
Model Name | Celerra NS700G Cluster / CLARiiON CX700x2 |
Processor | 3.06GHz Intel Xeon P4 |
# of Processors | 4 (2 per Data Mover) |
Primary Cache | Execution Trace Cache 12K uOPs + Data Cache 8KB |
Secondary Cache | 512KB (unified) |
Other Cache | N/A |
UPS | N/A |
Other Hardware | N/A |
Memory Size | 8 GB (4GB per Data Mover) |
NVRAM Size | N/A |
NVRAM Type | N/A |
NVRAM Description | N/A |
Server Software |
OS Name and Version | Dart 5.2 |
Other Software | Redhat Linux 7.2 on Control Station |
File System | UxFS |
NFS version | 3 |
Server Tuning |
Buffer Cache Size | Dynamic |
# NFS Processes | 4 per Data Mover |
Fileset Size | 689.3 GB |
|
Network Subsystem |
Network Type | Jumbo Gigabit Ethernet |
Network Controller Desc. | Gigabit Ethernet Controller |
Number Networks | 1 |
Number Network Controllers | 4 (2 per Data Mover) |
Protocol Type | TCP |
Switch Type | Cisco 6509 Gbit Switch (Jumbo) |
Bridge Type | N/A |
Hub Type | N/A |
Other Network Hardware | N/A |
Disk Subsystem and Filesystems |
Number Disk Controllers | 8 [2 per Storage Processor (SP), 4 SPs] |
Number of Disks | 248 |
Number of Filesystems | 2 |
File System Creation Ops | N/A |
File System Config | Each filesystem is striped (8KB element size), across 120 disk (40 LUNs) |
Disk Controller | Integrated 2Gb Fibre Channel |
# of Controller Type | 8 [2 per SP, 4 SPs] |
Number of Disks | 248 (dual ported) |
Disk Type | Seagate Fibre Channel 146GB 10k-rpm |
File Systems on Disks | OS and UxFS Log1 (5), UxFS Log2 (3), Filesystem fs1 (120), Filesystem fs2 (120) |
Special Config Notes | 4GB cache per SP on storage array. 3072 MB mirrored write cache per SP. See notes below. |
|