Lenovo Global Technology ThinkEdge SE100 SPECpower_ssj2008 = 15,182 overall ssj_ops/watt
Test Sponsor: Lenovo Global Technology SPEC License #: 9017 Test Method: Single Node
Tested By: Lenovo Global Technology Test Location: Beijing, China Test Date: Jun 3, 2025
Hardware Availability: May-2025 Software Availability: Feb-2025 Publication: Jun 23, 2025
System Source: Single Supplier System Designation: Server Power Provisioning: Line-powered
Benchmark Results Summary
Performance Power Performance to Power Ratio
Target Load Actual Load ssj_ops Average Active Power (W)
100% 100.1% 1,031,011 46.0 22,417
90% 89.9% 925,957 43.6 21,229
80% 80.0% 823,964 41.2 19,996
70% 70.0% 720,906 38.7 18,620
60% 59.8% 615,555 36.1 17,038
50% 50.1% 516,325 33.8 15,264
40% 39.9% 411,437 31.3 13,147
30% 30.2% 310,930 29.1 10,702
20% 20.0% 205,792 26.7 7,713
10% 9.9% 102,418 24.3 4,207
Active Idle 0 22.2 0
∑ssj_ops / ∑power = 15,182
Graph of results
System Under Test
Set: 'sut'
Set Identifier: sut
Set Description: System Under Test
# of Identical Nodes: 1
Comment: 'SUT'
Hardware
Hardware Vendor: Lenovo Global Technology
Model: ThinkEdge SE100
Form Factor: 1U
CPU Name: Intel Core Ultra 7 255H
CPU Characteristics: 16 Core, 2.0GHz, 24MB L3 Cache
CPU Frequency (MHz): 2000
CPU(s) Enabled: 16 cores, 1 chip, 16 cores/chip
Hardware Threads: 16 (1 / core)
CPU(s) Orderable: 1 chip
Primary Cache: 64 KB I + 48 KB D on chip per core
Secondary Cache: 3 MB I+D on chip per core
Tertiary Cache: 24 MB I+D on chip per chip
Other Cache: None
Memory Amount (GB): 16
# and size of DIMM: 2 x 8192 MB
Memory Details: 8GB 1Rx16 PC5-6400B; slots 1 and 2 populated
Power Supply Quantity and Rating (W): 1 x 140
Power Supply Details: Lenovo P/N:4X27A92699
Disk Drive: 1 x 240GB M.2 SSD P/N:4XB7A89422
Disk Controller: Integrated SATA controller
# and type of Network Interface Cards (NICs) Installed: 1 x 1GbE RJ45
NICs Enabled in Firmware / OS / Connected: 4/4/1
Network Speed (Mbit): 1000
Keyboard: None
Mouse: None
Monitor: None
Optical Drives: No
Other Hardware: None
Software
Power Management: Enabled (see SUT Notes)
Operating System (OS): Ubuntu 24.04.2 LTS 64-bit
OS Version: Linux 6.8.0-60-generic
Filesystem: ext4
JVM Vendor: Oracle Corporation
JVM Version: Java HotSpot(TM) 64-Bit Server VM (build 17.0.10+11-LTS-240, mixed mode, sharing), version 17.0.10
JVM Command-line Options: -server -Xmn450m -Xms512m -Xmx512m -XX:ParallelGCThreads=2 -XX:+UseLargePages -XX:InlineSmallCode=1500 -XX:AutoBoxCacheMax=20000 -XX:+UseParallelGC -XX:FreqInlineSize=2500 -XX:CompileThresholdScaling=210
JVM Affinity: for each physicalCore { numactl -C physicalCoreId }
JVM Instances: 16
JVM Initial Heap (MB): 512
JVM Maximum Heap (MB): 512
JVM Address Bits: 64
Boot Firmware Version: DZE104U
Management Firmware Version: DZX310C
Workload Version: SSJ 1.2.10
Director Location: Controller
Other Software: None
Boot Firmware Settings
Management Firmware Settings
None
System Under Test Notes
Controller System
Hardware
Hardware Vendor: Lenovo Global Technology
Model: ThinkSystem SR650
CPU Description: 2 x Intel Xeon Gold 5218
Memory amount (GB): 768
Software
Operating System (OS): Microsoft Windows Server 2019 DataCenter - Version 1809 (OS Build 17763.2268)
JVM Vendor: Oracle Corporation
JVM Version: Oracle Java HotSpot(TM) 64-Bit Server VM (build 24.80-b11, mixed mode), version 1.7.0_80
CCS Version: 1.2.6
Measurement Devices
Power Analyzer pwr1
Hardware Vendor: YOKOGAWA, Inc.
Model: WT310E
Serial Number: C3UG05013E
Connectivity: USB
Input Connection: Default
Metrology Institute: China National Accreditation Service for Conformity Assessment (CNAS)
Accredited by: CHINA CEPREI LABORATORY CALIBRATION & TESTING CENTRB
Calibration Label: 1GA24011968-0001
Date of Calibration: 25-Sep-2024
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
PTDaemon Version: 1.11.1-462c978e-20240907
Setup Description: Connected to PSU 1
Temperature Sensor temp1
Hardware Vendor: Digi International, Inc.
Model: Watchport/H
Driver Version: 5.70.105.0
Connectivity: USB
PTDaemon Host System: same as CCS
PTDaemon Host OS: same as CCS
Setup Description: 50 mm in front of SUT main intake
Notes
Aggregate Electrical and Environmental Data
Target Load Average Active Power (W) Minimum Ambient Temperature (°C)
100% 46.0 22.6
90% 43.6 22.8
80% 41.2 22.9
70% 38.7 23.2
60% 36.1 23.4
50% 33.8 23.6
40% 31.3 23.9
30% 29.1 24.1
20% 26.7 24.2
10% 24.3 24.0
Active Idle 22.2 23.8
Line Standard Minimum Temperature (°C) Elevation (m)
220V / 50 Hz / 1 phase / 2 wires 22.6 43
Aggregate Performance Data
Target Load Actual Load ssj_ops
Target Actual
Calibration 1     864,734
Calibration 2     1,014,568
Calibration 3     1,045,857
ssj_ops@calibrated=1,030,213
100% 100.1% 1,030,213 1,031,011
90% 89.9% 927,191 925,957
80% 80.0% 824,170 823,964
70% 70.0% 721,149 720,906
60% 59.8% 618,128 615,555
50% 50.1% 515,106 516,325
40% 39.9% 412,085 411,437
30% 30.2% 309,064 310,930
20% 20.0% 206,043 205,792
10% 9.9% 103,021 102,418
Active Idle   0 0
Graph of results